Independent 3rd Party Testing Results - Mito Red Original 2.0 Series

Posted June 12, 2023

We excited to share results from recent independent, third party testing performed on Mito Red's new MitoMIN 2.0, MitoMID 2.0, MitoMEGA 2.0, and MitoMAX 2.0

These tests were performed by Lightlab International, an independent photometric and radiometric testing laboratory in Allentown, Pennsylvania that provides testing services for the lighting industry. LightLab is ISO-accredited and is a recognized testing laboratory for energy efficiency certification and listing programs including the DesignLights Consortium (DLC) and the California Energy Commission (CEC) programs. 

MitoMIN 2.0

The 3rd party testing results show that the MitoMIN 2.0 delivers an impressive 21,720 Joules in 10 minutes.

MitoMIN2.0 test results

 

To understand the calculations, Total Radiant Flux of 36,257 milliWatts = 36.2 Watts.

1 Watt = 1 Joule Per Second

So to calculate Joules in 10 minutes it is simply 36.2 Watts X 10 minutes X 60 seconds / minute = 21,720 Joules.

 

MitoMID 2.0

The 3rd party testing results show that the MitoMID 2.0 delivers an impressive 37,500 Joules in 10 minutes.

To understand the calculations, Total Radiant Flux of 62,526 milliWatts = 62.5 Watts.

1 Watt = 1 Joule Per Second

So to calculate Joules in 10 minutes it is simply 62.5 Watts X 10 minutes X 60 seconds / minute = 37,500 Joules.

 

MitoMAX 2.0

The 3rd party testing results show that the MitoMAX 2.0 delivers an impressive 68,040 Joules in 10 minutes.

MitoMAX 2.0 Test report

 

To understand the calculations, Total Radiant Flux of 113,413 milliWatts = 113.4 Watts.

1 Watt = 1 Joule Per Second

So to calculate Joules in 10 minutes it is simply 113.4 Watts X 10 minutes X 60 seconds / minute = 68,040 Joules.

 

MitoMEGA 2.0

The 3rd party testing results show that the MitoMEGA 2.0 delivers an impressive 106,560 Joules in 10 minutes.

To understand the calculations, Total Radiant Flux of 177,591 milliWatts = 177.6 Watts.

1 Watt = 1 Joule Per Second

So to calculate Joules in 10 minutes it is simply 177.6 Watts X 10 minutes X 60 seconds / minute = 106,560 Joules.

We are going to be publishing a comprehensive summary of all of our independent testing docs so stay tuned! 