This in vivo study investigated whether the bioactivity of anodizing coating, produced by plasma electrolytic oxidation (PEO), on mini-plate in femur fracture could be improved with the association of photobiomodulation (PBM) therapy. From the 20 ovariectomized Wistar female rats, 8 were used for model characterization, and the remaining 12 were divided into four groups according to the use of PBM therapy by diode laser (808 nm; power: 100 mW; energy: 6.0 J; energy density: 212 J/cm2; power density: 3.5 W/cm2) and the type of mini-plate surface (commercially pure titanium mini-plate -cpTi- and PEO-treated mini-plate) as follow: cpTi; PEO; cpTi/PBM; and PEO/PBM. After 60 days of surgery, fracture healing underwent microstructural, bone turnover, histometric, and histologic adjacent muscle analysis.